Tripp-Lite PDUMH32HVNET Switched PDU
  • Tripp-Lite PDUMH32HVNET Switched PDU
  • Tripp-Lite PDUMH32HVNET Switched PDU
  • Tripp-Lite PDUMH32HVNET Switched PDU
  • Tripp-Lite PDUMH32HVNET Switched PDU
  • Tripp-Lite PDUMH32HVNET Switched PDU
  • Tripp-Lite PDUMH32HVNET Switched PDU
  • Tripp-Lite PDUMH32HVNET Switched PDU

PDUMH32HVNET Switched, Metered, 32A 2U horizontal rack PDU supports 7.3kW capacity at 230V. Includes attached Blue 230V IEC-309 32A (2P+E) input plug and 16 230V C13 switched outlets arranged in two separately breakered 8 outlet banks. Visual and remote current monitoring tracks the current for each 8 outlet bank separately, plus offers total power consumption for all 16 outlets combined. Supports 2U installation in 19 inch rackmount applications. Included cord retention ties keep vital network equipment plugged in and continuously powered.

Tripp Lite Switched Rack Power Distribution Units enable a variety of advanced network control and monitoring functions by giving IT Managers the ability to turn on, turn off, recycle or lock-out power to each individual receptacle and remotely monitor PDU power consumption and in-rack environmental conditions. Switched PDU systems can be accessed, configured and controlled through secure web, SNMP or Telnet Interface. Individually switched outlets can be controlled via a built-in web/network interface, enabling remote reboot of unresponsive network hardware. User defined power-up and power-down outlet sequences ensure proper operation of interdependent IT systems and prevent inrush-related overloads as devices are powered on. Programmable load-shedding of less critical devices at user-defined intervals extends UPS uptime in response to power failures. Unused PDU outlets can be electronically locked-off to prevent powering of unauthorized hardware. PDU power consumption (current) is displayed locally and can be monitored via the web/network interface, with user-defined alarms to warn of potential overloads before critical IT mains or branch breakers trip. Optional ENVIROSENSE temperature/humidity probe enables remote monitoring of in-rack environmental conditions and alarms for up to 4 user supplied contact-closure sensors. Supports real-time monitoring, notification and logging of all on-board reporting functions with user-specified alarm thresholds and actions for each reported condition. Switched PDU systems can be accessed, configured and controlled through secure web, SNMP or Telnet Interface.

Key Features

  • 230V Switched PDU with built-in web/network interface in 2U rackmount form factor; 32A capacity
  • Blue 230V IEC-309 32A (2P+E) input cable; 12 ft. / 3.6m power cable included
  • 16 switched C13 outlets
  • 2U horizontal rackmount form factor
  • Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
  • Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
  • Network interface provides PDU control and data regarding input voltage, frequency and loading information
  • Digital display reports load level information in amps
  • Supports user-specified alarm notification thresholds
  • In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
  • DHCP/Manual configuration support
  • 10/100 Mbps auto-sensing
  • Real-time clock backup maintains the time of day and date even if the PDU is unpowered
  • Tiered access privileges allow an administrator and a guest to login via web browser
  • Alert notifications via email or SNMP traps offer immediate event notification
  • Firmware upgrade ability supports future product enhancements
  • Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
  • Fully compatible with FREE PowerAlert Network Management System / NMS Software
  • Included cord retention brackets
  • TAA Compliant Version Available - Order Tripp Lite PDUMH32HVNETAA


Package Includes

  • Switched PDU
  • Rack installation brackets
  • Cable retention ties
  • SNMPWEBCARD configuration cable
  • PowerAlert software kit
  • User manual
AC outlet typesC13 coupler
AC outlets quantity16
Cable length3.65 m
Colour of productBlack
Dimensions (WxDxH)445 x 317.5 x 89 mm
Input frequency50/60 Hz
LED indicatorsYes
Load capacity7360 VA
MaterialSteel
Maximum current32 A
MountingHorizontal
Nominal input voltage230 V
Nominal output voltage230 V
Operating relative humidity (H-H)0 - 95 %
PDU typesSwitched
Rack mountingYes
Weight6.2 kg

Tripp-Lite PDUMH32HVNET Switched PDU

Tripp-Lite PDUMH32HVNET, 230 V, 50/60 Hz, 32 A, C13 coupler, 230 V, 7360 VA

PDUMH32HVNET

Out of Stock

£874.90